PCB Content in Capacitor Cells
Phone :
586.979.9955
Fax :
586.979.9484
SEARCH
|
REQUEST A QUOTE
History
Affiliates
Fixed
Automatic
MCC Traymount
Custom
Fixed
Automatic
Active
480 V Product Selection
600 V Product Selection
Power Factor Correction Capacitors
Harmonic Filters
Line Reactors
Medium Voltage Applications
Construction Features
Model Selection
Performance
PFC Capacitor Cells
Replacement Parts
Versatex and VAR Controls
Improving power Factor
Elimination of Penalty Dollars
Additional Capacity in Electrical System
Reduction of I2R Losses
Analysis of Utility Bills
Method #1 Capacitor at Load
Method #2 Fixed Capacitor Bank
Method #3 Automatic Capacitor Bank
Method #4 Combination of Methods
Harmonic Distortion
Definitions
Basic Relations
Definitions
Harmonic Sources
Problems Resulting From Harmonics
The Need to Address Harmonics
Locating the Source of Harmonics
Solving the Harmonic Problem
Require Line Reactors
Line Reactors Used
Line Reactors Connected
Typical Applications
Power Factor Correction
Harmonic Mitigation
Line Reactors
Specifications
Technical Bulletins - Capacitalks
Troubleshooting
PFCC Manuals and Resources
Harmonic Filter Manuals and Resources
FAQ
Engineering Resources
Product Resources
Case Studies
Representatives
Map
Home
About
Products
Services
Resources
News
Contact Us
Home
About
Products
Services
Replacement Parts
Versatex and VAR Controls
Resources
Contact Us
Products
Power Factor Correction Capacitors
Fixed
Automatic
MCC Traymount
Custom
Harmonic Filters
Fixed
Automatic
Active
Services
>
Replacement Parts
PCB Content in Older Capacitors
PCB & NON-PCB CAPACITOR CELL DESIGNATIONS
(PDF Version)
PCB CELL
MZI ASSEMBLY IDENTIFICATION
B5 & G5 - Suffix
1976 and Earlier
GFL - Suffix
1976 or 1977
CELL IDENTIFICATION
UCV & UCF - Suffix
1977 and Earlier
FLUID TRADE NAMES
Chlorinol, Chlorophen, Askarel
1977 and Earlier
NON-PCB CELL
MZI ASSEMBLY IDENTIFICATION
EL, EX - Suffix
1978 - 1979
VL, VX, UL, UX - Suffix
1979 - 1982
VLM, VXM, VNM - Suffix
1983 - 1985
KIM, KNM, KPM - Prefix
1986 - 1998
CELL IDENTIFICATION
SKG OR NCEF - Suffix
1978 - 1983
PCEM & PCEMA - Suffix
1984 - 1998
FLUID TRADE NAMES
Eccol & Sevenol
1978 - 1983
Jayflex DINP
1984 - 1998
NON-PCB DRY-CELL
MZI ASSEMBLY IDENTIFICATION
KID, KND, KPD - Prefix
1986 - 1998
KIM, KNM, KPM - Prefix
1999 - Present
CELL IDENTIFICATION
PCDM, PCDMA - Suffix
1986 - 1998
PCDMF - Suffix
1999 - Present
FLUID TRADE NAMES
Vorite 683
1999 - Present
DIELECTRIC FLUID CONTENT OF PCB CAPACITOR CELLS USED IN MZI CAPACITOR ASSEMBLIES
VOLTAGE
kVAr SIZE
PART NO.*
OIL WEIGHT
OIL VOLUME
240 VOLT CELL
0.5
1.0
1.5
2.0
2.5
X23 UCV
123 UCV
1x23 UCV
223 UCV
2x23 UCV
0.90 /lb.
1.47
1.81
1.97
2.27
.078 /gal.
.128
.157
.198
.264
480 VOLT CELL
1.0
1.5
2.0
2.5
3.0
4.0
5.0
6.0
7.5
143 UCV
1X43 UCV
243 UCV
2X43 UCV
343 UCV
443 UCV
543 UCV
643 UCF
7X43 UCF
0.82
1.03
1.23
1.44
1.64
2.05
2.62
1.73
2.03
.071
.089
.107
.125
.143
.178
.228
.151
.176
600 VOLT CELL
1.0
1.5
2.0
2.5
3.0
4.0
5.0
6.0
7.5
163 UCV
1X63 UCV
263 UCV
2X63 UCV
363 UCV
463 UCV
563 UCV
663 UCF
7X63 UCF
0.82
1.03
1.23
1.44
1.65
2.05
2.62
1.73
2.03
.071
.089
.107
.125
.143
.178
.228
.151
.176
*Part numbers given for cells containing Chlorinol fluid. Cells with other types of PCB may have different part numbers. Note: Since dielectric fluids in these cells were PCB based, PCB content is greater than 500,000 parts per million.
This document originally published by Myron Zucker, June 20, 1986.
MYRON ZUCKER INC. products are designed to:
Improve power factor
Eliminate utility penalties or surcharges
Increase available distribution capacity
Mitigate harmonic distortion
Protect sensitive equipment
Decrease downtime
Reduce line losses and associated cost